Current, powered by GE

GE432MAXPN/ULTRA

78627

GE LFL UltraMax™Professional Series Electronic High Efficiency Multivolt Instant Start Ballast

Features & Benefits
  • Energy saving high efficiency instant start electronic ballast (> 90%)
  • Multi-Voltage Technology handles voltage from 120 to 277V
  • UL Type CC Rating provides protection against arcing in electrical devices.
  • Anti-Striation Control for better light quality, with no striations.
  • UL 55C Ambient Rating - HighTemperature Protection Circuit
  • Cold temperature -20F Minimum Starting Temperature

GENERAL CHARACTERISTICS
Ambient Temp [Max]
131  °F
Ambient Temp [Min]
-22  °F
Ballast Factor
Normal 
Ballast Type
High Efficiency Multivolt Instant Start 
Case Temperature (Max)
70  °C
Line Voltage Regulation (+/-)
10% 
Classification (Regulations)
cUL Listed 
FCC - CLASS A Non-Consumer 
UL Class P 
UL Listed 
UL Type 1 Outdoor 
UL Type CC 
UL Type HL 
Meets ANSI Standard C82.11-Cons 2002 
Meets ANSI Standard C62.41-1991 
NEMA Premium® 
Product is compliant with material restriction requirements of RoHS 
Sound Rating
A (20-24 decibels) 
Starting Method
Instant start 
Product Technology
Linear Fluorescent 
Lamp Wiring
Parallel 
Power Factor Correction
Active 
Lamp Count
ELECTRICAL CHARACTERISTICS
Supply Current Frequency
50 
DIMENSIONS
Weight
0.9  lb
Exit Type
 
Remote Mount Distance
18.0  ft
PACKAGING INFORMATION
Alternative Unit Of Measure
CASE
Standard Package Quantity
10
Ean UPC
043168786270
Standard Package GTIN
10043168786277
Pack Level Description
Case
No Of Items Per Standard Package
10
Sales Unit
Case
UCC
043168786270
BALLAST DIMENSION
Case dimensions
Length
9.5 in
Width
1.3 in
Height
1.0 in
Mounting dimensions
Mount Length
8.89 in
Mount Width
0.88 in
Mount Slots
0.312 in
LEAD LENGTH
Lead Color
Quality of Leads Per Color
Lead Exit Type
Lead Size
Lead Length
Blue
2
Right
31
31 in
Black
1
Left
25
25 in
Red
2
Right
31
31 in
White
1
Left
25
25 in
Yellow
2
Left
39
39 in
Design Files
(0)
select all
bal_dim_cfl_b_300x300.eps
Safety & Performance
  • cUL Listed
  • FCC - CLASS A Non-Consumer
  • UL Class P
  • UL Listed
  • UL Type 1 Outdoor
  • UL Type CC
  • UL Type HL
  • Meets ANSI Standard C82.11-Cons 2002
  • Meets ANSI Standard C62.41-1991
Warning and Cautions

Warnings:

  • Risk of Electric Shock
    • Properly ground ballast and fixture.
    • Turn power off before servicing--see instructions.

F32T8/WM

#of lamps:3

Line Volts Dimming Levels System Watts Nom. Line Current System Ballast Factor Ballast Efficacy Factor Power Factor % (>=) THD % (<=) Min. Starting Temp
120  V 84  W 0.71  A 0.91 1 0.99 10 50  °F
277  V 83  W 0.31  A 0.91 1 0.98 10 50  °F

#of lamps:4

Line Volts Dimming Levels System Watts Nom. Line Current System Ballast Factor Ballast Efficacy Factor Power Factor % (>=) THD % (<=) Min. Starting Temp
120  V 102  W 0.85  A 0.87 1 0.99 10 50  °F
277  V 100  W 0.37  A 0.87 1 0.98 10 50  °F

F17T8

#of lamps:3

Line Volts Dimming Levels System Watts Nom. Line Current System Ballast Factor Ballast Efficacy Factor Power Factor % (>=) THD % (<=) Min. Starting Temp
120  V 50  W 0.42  A 0.96 2 0.99 10 -22  °F System Spec
277  V 50  W 0.19  A 0.96 2 0.95 10 -22  °F System Spec

#of lamps:4

Line Volts Dimming Levels System Watts Nom. Line Current System Ballast Factor Ballast Efficacy Factor Power Factor % (>=) THD % (<=) Min. Starting Temp
120  V 61  W 0.52  A 0.87 1 0.99 10 -22  °F System Spec
277  V 60  W 0.23  A 0.87 1 0.96 10 -22  °F System Spec

F25T12

#of lamps:3

Line Volts Dimming Levels System Watts Nom. Line Current System Ballast Factor Ballast Efficacy Factor Power Factor % (>=) THD % (<=) Min. Starting Temp
277  V 74  W 0.27  A 0.87 1 0.97 10 0  °F System Spec
120  V 75  W 0.63  A 0.87 1 0.99 10 0  °F System Spec

#of lamps:4

Line Volts Dimming Levels System Watts Nom. Line Current System Ballast Factor Ballast Efficacy Factor Power Factor % (>=) THD % (<=) Min. Starting Temp
120  V 90  W 0.75  A 0.79 1 0.99 10 0  °F System Spec
277  V 89  W 0.33  A 0.79 1 0.98 10 0  °F System Spec

F28T8

#of lamps:3

Line Volts Dimming Levels System Watts Nom. Line Current System Ballast Factor Ballast Efficacy Factor Power Factor % (>=) THD % (<=) Min. Starting Temp
120  V 77  W 0.66  A 0.93 1 0.99 10 50  °F System Spec
277  V 76  W 0.29  A 0.93 1 0.98 10 50  °F System Spec

#of lamps:4

Line Volts Dimming Levels System Watts Nom. Line Current System Ballast Factor Ballast Efficacy Factor Power Factor % (>=) THD % (<=) Min. Starting Temp
120  V 94  W 0.8  A 0.84 1 0.99 10 50  °F System Spec
277  V 92  W 0.34  A 0.87 1 0.98 10 50  °F System Spec

F32T8/25W

#of lamps:3

Line Volts Dimming Levels System Watts Nom. Line Current System Ballast Factor Ballast Efficacy Factor Power Factor % (>=) THD % (<=) Min. Starting Temp
277  V 71  W   0.89 1 0.97 10 50  °F System Spec

#of lamps:4

Line Volts Dimming Levels System Watts Nom. Line Current System Ballast Factor Ballast Efficacy Factor Power Factor % (>=) THD % (<=) Min. Starting Temp
277  V 86  W   0.87 1 0.98 10 50  °F System Spec

F29T8

#of lamps:3

Line Volts Dimming Levels System Watts Nom. Line Current System Ballast Factor Ballast Efficacy Factor Power Factor % (>=) THD % (<=) Min. Starting Temp
120  V 85  W 0.71  A 0.95 1.0  
277  V 82  W 0.3  A 0.95 0.98  

#of lamps:4

Line Volts Dimming Levels System Watts Nom. Line Current System Ballast Factor Ballast Efficacy Factor Power Factor % (>=) THD % (<=) Min. Starting Temp
120  V 101  W 0.85  A 0.86 1.0  
277  V 98  W 0.36  A 0.86 0.99  

F25T8/WM

#of lamps:3

Line Volts Dimming Levels System Watts Nom. Line Current System Ballast Factor Ballast Efficacy Factor Power Factor % (>=) THD % (<=) Min. Starting Temp
120  V 61  W 0.51  A 0.93 1 1.0 10 -22  °F System Spec
277  V 60  W 0.23  A 0.93 1 0.97 10 -22  °F System Spec

#of lamps:4

Line Volts Dimming Levels System Watts Nom. Line Current System Ballast Factor Ballast Efficacy Factor Power Factor % (>=) THD % (<=) Min. Starting Temp
277  V 74  W 0.27  A 0.86 1 0.98 10 -22  °F System Spec
120  V 75  W 0.63  A 0.86 1 1.0 10 -22  °F System Spec

F17T8/WM

#of lamps:3

Line Volts Dimming Levels System Watts Nom. Line Current System Ballast Factor Ballast Efficacy Factor Power Factor % (>=) THD % (<=) Min. Starting Temp
120  V 45  W 0.38  A 0.97 2 1.0 10 -22  °F System Spec
277  V 45  W 0.17  A 0.97 2 0.95 10 -22  °F System Spec

#of lamps:4

Line Volts Dimming Levels System Watts Nom. Line Current System Ballast Factor Ballast Efficacy Factor Power Factor % (>=) THD % (<=) Min. Starting Temp
120  V 53  W 0.44  A 0.87 1 1.0 10 -22  °F System Spec
277  V 52  W 0.2  A 0.87 1 0.96 10 -22  °F System Spec

FE15T8

#of lamps:3

Line Volts Dimming Levels System Watts Nom. Line Current System Ballast Factor Ballast Efficacy Factor Power Factor % (>=) THD % (<=) Min. Starting Temp
277  V 41  W 0.16  A 0.85 2 0.93 15 0  °F System Spec
120  V 41  W 0.34  A 0.85 2 0.99 10 0  °F System Spec

#of lamps:4

Line Volts Dimming Levels System Watts Nom. Line Current System Ballast Factor Ballast Efficacy Factor Power Factor % (>=) THD % (<=) Min. Starting Temp
277  V 48  W 0.18  A 0.77 2 0.95 10 0  °F System Spec
120  V 48  W 0.41  A 0.77 2 0.99 10 0  °F System Spec

F31T8

#of lamps:3

Line Volts Dimming Levels System Watts Nom. Line Current System Ballast Factor Ballast Efficacy Factor Power Factor % (>=) THD % (<=) Min. Starting Temp
120  V 87  W 0.74  A 0.91 0.99   System Spec
277  V 85  W 0.31  A 0.91 0.99   System Spec

#of lamps:4

Line Volts Dimming Levels System Watts Nom. Line Current System Ballast Factor Ballast Efficacy Factor Power Factor % (>=) THD % (<=) Min. Starting Temp
120  V 106  W 0.89  A 0.84 0.99   System Spec
277  V 104  W 0.38  A 0.84 0.99   System Spec

F32T8

#of lamps:3

Line Volts Dimming Levels System Watts Nom. Line Current System Ballast Factor Ballast Efficacy Factor Power Factor % (>=) THD % (<=) Min. Starting Temp
120  V 92  W 0.78  A 0.96 1 0.98 10 -22  °F System Spec
277  V 91  W 0.34  A 0.96 1 0.98 10 -22  °F System Spec

#of lamps:4

Line Volts Dimming Levels System Watts Nom. Line Current System Ballast Factor Ballast Efficacy Factor Power Factor % (>=) THD % (<=) Min. Starting Temp
120  V 110  W 0.93  A 0.88 1 0.99 10 -22  °F System Spec
277  V 108  W 0.4  A 0.88 1 0.98 10 -22  °F System Spec

F25T8

#of lamps:3

Line Volts Dimming Levels System Watts Nom. Line Current System Ballast Factor Ballast Efficacy Factor Power Factor % (>=) THD % (<=) Min. Starting Temp
120  V 73  W 0.61  A 0.9 1 0.99 10 -22  °F System Spec
277  V 72  W 0.26  A 0.9 1 0.97 10 -22  °F System Spec

#of lamps:4

Line Volts Dimming Levels System Watts Nom. Line Current System Ballast Factor Ballast Efficacy Factor Power Factor % (>=) THD % (<=) Min. Starting Temp
120  V 87  W 0.73  A 0.82 1 0.99 10 -22  °F System Spec
277  V 85  W 0.31  A 0.82 1 0.98 10 -22  °F System Spec

F26T8

#of lamps:3

Line Volts Dimming Levels System Watts Nom. Line Current System Ballast Factor Ballast Efficacy Factor Power Factor % (>=) THD % (<=) Min. Starting Temp
120  V 76  W 0.64  A 0.91 1.0   System Spec
277  V 74  W 0.28  A 0.92 0.98   System Spec

#of lamps:4

Line Volts Dimming Levels System Watts Nom. Line Current System Ballast Factor Ballast Efficacy Factor Power Factor % (>=) THD % (<=) Min. Starting Temp
120  V 91  W 0.76  A 0.82 1.0   System Spec
277  V 88  W 0.32  A 0.82 0.99   System Spec

Suggested Products

Description
Product Code
Watts
Lumen
GE-432-MAX-N/ULTRA